Operators Guide Inspector 4000
002-5564 RJS, Minneapolis, MN
29
ANSI Analysis Screens
Press Select again to display the first technical Data Analysis screen.
Ref Decode A
Decodable 78% A
This screen shows the grades for the symbols reference Decode and Decodability.
Press Select to display the next screen:
Sym. Cntr 84% A
Rmin/Rmx 01% A
This screen shows the ANSI symbol contrast on the top row and Rmin/Rmax
calculation on the bottom row.
Press Select to display the next screen:
Ecmin 66% A
MODulation 78% A
This screen shows the symbols ANSI Minimum Edge Contrast value on the top row
and the Modulation value on the bottom row.